Addressing Table

Switch Port Assignment Specifications

Objectives

Part 1: Configure VLANs
Part 2: Configure Spanning Tree PVST+ and Load Balancing
Part 3: Configure PortFast and BPDU Guard

Background

In this activity, you will configure VLANs and trunks, and examine and configure the Spanning Tree Protocol primary and secondary root bridges. You will also optimize the switched topology using PVST+, PortFast, and BPDU guard.

Part 1: Configure VLANs

Refer to the topology diagram to determine which switch ports (S1, S2, and S3) are activated for end-user device access. These three ports will be configured for access mode and enabled with the no shutdown command.

Step 1: Enable the user ports on S1, S2, and S3 in access mode.

S1(config-if)#switchport mode access
S1(config-if)#no shutdown

S2(config-if)#switchport mode access
S2(config-if)#no shutdown

S3(config-if)#switchport mode access
S3(config-if)#no shutdown

Step 2: Create VLANs.
Using the appropriate command, create VLANs 10, 20, 30, 40, 50, 60, 70, 80, and 99 on all of the switches.

S1(config)#vlan 10
S1(config-vlan)#vlan 20
S1(config-vlan)#vlan 30
S1(config-vlan)#vlan 40
S1(config-vlan)#vlan 50
S1(config-vlan)#vlan 60
S1(config-vlan)#vlan 70
S1(config-vlan)#vlan 80
S1(config-vlan)#vlan 99

S2(config)#vlan 10
S2(config-vlan)#vlan 20
S2(config-vlan)#vlan 30
S2(config-vlan)#vlan 40
S2(config-vlan)#vlan 50
S2(config-vlan)#vlan 60
S2(config-vlan)#vlan 70
S2(config-vlan)#vlan 80
S2(config-vlan)#vlan 99

S3(config)#vlan 10
S3(config-vlan)#vlan 20
S3(config-vlan)#vlan 30
S3(config-vlan)#vlan 40
S3(config-vlan)#vlan 50
S3(config-vlan)#vlan 60
S3(config-vlan)#vlan 70
S3(config-vlan)#vlan 80
S3(config-vlan)#vlan 99

Step 3: Assign VLANs to switch ports.

Port assignments are listed in the table at the beginning of the activity. Save your configurations after assigning switch ports to the VLANs.

S1(config-vlan)#int f0/6
S1(config-if)#switchport access vlan 30

S2(config-vlan)#int f0/18
S2(config-if)#switchport access vlan 20

S3(config-vlan)#int f0/11
S3(config-if)#switchport access vlan 10

Step 4: Verify the VLANs.
Use the show vlan brief command on all switches to verify that all VLANs are registered in the VLAN table.

S1(config-if)#do show vlan brief

VLAN Name Status Ports


1 default active Fa0/1, Fa0/2, Fa0/3, Fa0/4
Fa0/5, Fa0/7, Fa0/8, Fa0/9
Fa0/10, Fa0/11, Fa0/12, Fa0/13
Fa0/14, Fa0/15, Fa0/16, Fa0/17
Fa0/18, Fa0/19, Fa0/20, Fa0/21
Fa0/22, Fa0/23, Fa0/24, Gig0/1
Gig0/2
10 VLAN0010 active
20 VLAN0020 active
30 VLAN0030 active Fa0/6
40 VLAN0040 active
50 VLAN0050 active
60 VLAN0060 active
70 VLAN0070 active
80 VLAN0080 active
99 VLAN0099 active
1002 fddi-default active
1003 token-ring-default active
1004 fddinet-default active
1005 trnet-default active
S1(config-if)#
On S2, and S3 follow command on S1

Step 5: Assign the trunks to native VLAN 99.

Use the appropriate command to configure ports F0/1 to F0/4 on each switch as trunk ports, and assign these trunk ports to native VLAN 99.

S1(config-if)#int range f0/1-4
S1(config-if-range)#switchport mode trunk
S1(config-if-range)#
%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1, changed state to down

%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1, changed state to up

%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/2, changed state to down

%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/2, changed state to up

%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/3, changed state to down

%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/3, changed state to up

%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/4, changed state to down

%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/4, changed state to up

S1(config-if-range)#switchport trunk native vlan 99
On S2, and S3 follow command on S1

a. Configure the management interface on all three switches with an address.Verify that the switches are correctly configured by pinging between them.

S1(config)#int vlan99
S1(config-if)#ip add 172.31.99.1 255.255.255.0
S2(config)#int vlan99
S2(config-if)#ip add 172.31.99.2 255.255.255.0
S3(config)#int vlan99
S3(config-if)#ip add 172.31.99.3 255.255.255.0

Part 2: Configure Spanning Tree PVST+ and Load Balancing
Because there is a separate instance of the spanning tree for every active VLAN, a separate root election is conducted for each instance. If the default switch priorities are used in root selection, the same root is elected for every spanning tree instance, as we have seen. This could lead to an inferior design. Some reasons to control the selection of the root switch include:

· The root switch is responsible for generating BPDUs for STP 802.1D and is the focal point for spanning tree to control traffic. The root switch must be capable of handling this additional load.
· The placement of the root defines the active switched paths in the network. Random placement is likely to lead to suboptimal paths. Ideally the root is in the distribution layer.
· Consider the topology used in this activity. Of the six trunks configured, only three are carrying traffic. While this prevents loops, it is a waste of resources. Because the root can be defined on the basis of the VLAN, you can have some ports blocking for one VLAN and forwarding for another. This is demonstrated below.

Step 1: Configure STP mode.

Use the spanning-tree mode command to configure the switches so they use PVST as the STP mode.

S1(config)#spanning-tree mode pvst
S2(config)#spanning-tree mode pvst
S3(config)#spanning-tree mode pvst

Step 2: Configure Spanning Tree PVST+ load balancing.

a. Configure S1 to be the primary root for VLANs 1, 10, 30, 50, and 70. Configure S3 to be the primary root for VLANs 20, 40, 60, 80, and 99. Configure S2 to be the secondary root for all VLANs.

S1(config)#spanning-tree vlan 1,10,30,50,70 root primary
S2(config)#spanning-tree vlan 1,10,20,30,40,50,60,70,80,99 root secondary
S3(config)#spanning-tree vlan 20,40,60,80,99 root primary

b. Verify your configurations using the show spanning-tree command.

S1(config)#do show spanning-tree
VLAN0001
Spanning tree enabled protocol ieee
Root ID Priority 24577
Address 0050.0F68.146E
This bridge is the root
Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec

Bridge ID Priority 24577 (priority 24576 sys-id-ext 1)
Address 0050.0F68.146E
Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec
Aging Time 20

Interface Role Sts Cost Prio.Nbr Type


Fa0/3 Desg FWD 19 128.3 P2p
Fa0/2 Desg FWD 19 128.2 P2p
Fa0/1 Desg FWD 19 128.1 P2p
Fa0/4 Desg FWD 19 128.4 P2p

VLAN0010
Spanning tree enabled protocol ieee
Root ID Priority 24586
Address 0050.0F68.146E
This bridge is the root
Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec

Bridge ID Priority 24586 (priority 24576 sys-id-ext 10)
Address 0050.0F68.146E
Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec
Aging Time 20

Interface Role Sts Cost Prio.Nbr Type

Fa0/3 Desg FWD 19 128.3 P2p
Fa0/2 Desg FWD 19 128.2 P2p
Fa0/1 Desg FWD 19 128.1 P2p
Fa0/4 Desg FWD 19 128.4 P2p

VLAN0020

On S2, and S3 follow command on S1

Part 3: Configure PortFast and BPDU Guard
Step 1: Configure PortFast on the switches.
PortFast causes a port to enter the forwarding state almost immediately by dramatically decreasing the time of the listening and learning states. PortFast minimizes the time it takes for the server or workstation to come online. Configure PortFast on the switch interfaces that are connected to PCs.

S1(config)#int f0/6
S1(config-if)#spanning-tree portfast
%Warning: portfast should only be enabled on ports connected to a single
host. Connecting hubs, concentrators, switches, bridges, etc… to this
interface when portfast is enabled, can cause temporary bridging loops.
Use with CAUTION

%Portfast has been configured on FastEthernet0/6 but will only
have effect when the interface is in a non-trunking mode.

On S2, and S3 follow command on S1

Step 2: Configure BPDU guard on the switches.
The STP PortFast BPDU guard enhancement allows network designers to enforce the STP domain borders and keep the active topology predictable. The devices behind the ports that have STP PortFast enabled are unable to influence the STP topology. At the reception of BPDUs, the BPDU guard operation disables the port that has PortFast configured. The BPDU guard transitions the port into the err-disable state, and a message appears on the console. Configure BPDU guard on switch interfaces that are connected to PCs.

S1(config)#int f0/6
S1(config-if)#spanning-tree bpduguard enable
S2(config)#int f0/18
S2(config-if)#spanning-tree bpduguard enable
S3(config)#int f0/11
S3(config-if)#spanning-tree bpduguard enable

Step 3: Verify your configuration.

Use the show running-configuration command to verify your configuration.